What is external device monitoring and how does it relate to machine safety?

ByDanielle Collins|April 1, 2022

Share

According to theMachinery Directive 2006/42/EC, technical protective measures should be used to reduce risks that cannot be avoided through safe design measures. These technical protective measures include safety devices such as door locks, covers, light curtains, and other equipment that monitors the machine movements. When the safety device controls and external device, such as a contactor or relay, to switch off power and stop a machine or prevent a hazardous function, the safety system must also implement measures for external device monitoring.


External device monitoring is typically required to achieve the highestmachine safety ratings— PLe Category 3 or 4 per ISO 13849-1, or SIL 3 per IEC 62061.


External device monitoring (EDM) is simply a means by which a safety or protective device, such as a light curtain or safety relay, monitors the state of external devices, such as contactors ormachine primary control elements(MPCEs), that are controlled by the safety device. If the external device is found to have an unsafe state, such as fused contacts or problems with wiring, the safety device will lockout.

Simply put, the safety device checks to ensure the external device (a contactor, for example) is de-energized when the safety device is triggered. It does this by using two normally closed (NC) contacts to monitor the status of the normally open (NO) external device contacts (such as machine power contacts). The NC monitoring contacts are mechanically linked to and positively guided by the NO contacts. In this positively-guided configuration, the NC and NO contacts operate together and cannot be closed simultaneously.

positively guided contacts
Mechanically-linked, positively guided contacts cannot be closed at the same time.
Image credit: Honeywell

When the safety device output is off, the NC monitoring contacts are closed, the contactor’s NO contacts are open, and 24 V is applied to the EDM input. However, if one of the NO contacting elements malfunctions and is closed — for example, by being fused — the monitoring NC contact cannot close, and the required voltage cannot be delivered to the EDM input.

Alternatively, when the safety device output is on, the NC monitoring contacts are open and the contactor’s NO contacts are closed. But if one of the NC monitoring contacts malfunctions (fused closed), the NO contacts cannot close. The safety device recognizes either of these abnormal conditions and prevents the machine or operation from re-starting.

External device monitoring can be implemented as either one-channel monitoring or two-channel monitoring. One-channel monitoring uses contacts that are wired in series, with feedback provided to the start condition of the safety device. Two-channel monitoring requires that the contacts be wired independently, and both NC contacts must be closed before the safety device can be reset. While one-channel monitoring can detect a malfunction in the operation of the contacts, two-channel monitoring can also detect a malfunction in the safety circuit wiring.

one-channel external device monitoring
With one-channel monitoring, the contactors (K3 and K4) are connected in series.
Images credit: Schneider Electric
two-channel external device monitoring
With two-channel monitoring, the contactors (K3 and K4) are connected independently, allowing wiring faults to be detected.


Filed Under:Motion Control Tips


Related ArticlesRead More >

New plastic bevel gears from igus offer lubrication-free motion
Dual Axis Yaw-and-Pitch Stages feature full range of motion of each axis under a single fixed point in space
Controllers, drives keep pace with automation demands
What machine safety functions address speed, and when are they used?

DESIGN GUIDE LIBRARY

“motion

Enews Sign Up

Motion Control Classroom

Design World Digital Edition

cover

Browse the most current issueof Design World and back issues in an easy to use high quality format. Clip, share and download with the leading design engineering magazine today.

EDABoard the Forum for Electronics

Top global problem solving EE forum covering Microcontrollers, DSP, Networking, Analog and Digital Design, RF, Power Electronics, PCB Routing and much more

EDABoard: Forum for electronics

Sponsored Content

  • WAGO’s custom designed interface wiring system making industrial applications easier
  • Global supply needs drive increased manufacturing footprint development
  • 10 Reasons to Specify Valve Manifolds
  • Case study: How a 3D-printed tool saved thousands of hours and dollars
  • WAGO’s smartDESIGNER Online Provides Seamless Progression for Projects
  • Stop over-designing: How to save time and money with a light-duty ring

Design World Podcasts

March 27, 2022
3D printing proves its value as manufacturing evolves
See More >
Engineering Exchange

The Engineering Exchange is a global educational networking community for engineers.

Connect, share, and learn today »

Design World
  • Advertising
  • About us
  • Contact
  • Manage your Design World Subscription
  • Subscribe
  • Design World Digital Network
  • Engineering White Papers
  • LEAP AWARDS

版权©2022 WTWH媒体LLC。Reserv所有权利ed. The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of WTWH Media
Privacy Policy|Advertising|About Us

Search Design World

  • Home
  • Technologies
    • 3D CAD
    • Electronics • electrical
    • Fastening & Joining
    • Factory automation
    • Linear Motion
    • Motion Control
    • Test & Measurement
    • Sensors
    • 流体动力
  • Learn
    • Ebooks / Tech Tips
    • Engineering Week
    • Future of Design Engineering
    • MC² Motion Control Classrooms
    • Podcasts
    • Videos
    • Webinars
  • LEAP AWARDS
  • 领导
    • 2022 Voting
    • 2021 Winners
  • Design Guide Library
  • Resources
    • 3D Cad Models
      • PARTsolutions
      • TraceParts
    • Digital Issues
      • Design World
      • EE World
    • Women in Engineering
  • Supplier Listings
We use cookies to personalize content and ads, to provide social media features and to analyze our traffic. We also share information about your use of our site with our social media, advertising and analytics partners who may combine it with other information that you’ve provided to them or that they’ve collected from your use of their services. You consent to our cookies if you continue to use this website. OkNoRead more