What is direct torque control (DTC) for AC induction motors?

ByDanielle Collins|May 8, 2020

Share

Variable frequency drives control AC induction motors through one of several control schemes. Scalar control (also referred to asV/Hzor V/f control) varies both the voltage and frequency of power supplied to the motor to maintain a fixed ratio between the two. This keeps the strength of the magnetic field at a constant level so that torque production remains stable. Scalar control is a simple, inexpensive control method, but it doesn’t allow precise control of motor speed.

Vector control (also referred to asfield oriented control, or FOC) controls the magnetizing and the torque-producing components of the stator current independently to control both motor speed and torque.

Another control method, known as direct torque control (DTC), is similar to field oriented control, in that it decouples torque and flux and controls them independently. But DTC controls motor torquedirectly, without a modulator, so torque response is much faster.


Direct torque control uses two control loops — a speed control loop and a torque control loop — that work together, along with an advanced motor model, to precisely predict stator flux and motor torque. Here’s how it works:

direct torque control

Image credit: ABB

1 –Two motor phase currents and the DC bus voltage are measured, along with theinverter’s switch positions. (Motor voltage is determined from the DC bus voltage and the inverter’s switch positions.)

2 –Motor current and voltage are fed to the motor model, which uses advanced mathematical algorithms to produce exact values of the stator flux and motor torque, along with shaft speed, every 25 μs (as fast as 12.5 μs in some drives).

3 –The actual torque and flux values are fed to the torque and flux comparators, which compare them to torque and flux reference values that are provided by the speed control loop (see #6).

The goals of the comparators are to hold the magnitudes of the torque and flux vectors within a narrow hysteresis band around the reference values. This is a primary factor in DTC’s ability to achieve fast torque response without overshoot.

4 –Torque and flux status signals are fed to the optimum pulse selector.

5 –The optimum pulse selector chooses the optimum voltage vector from a lookup table and, based on this, sends pulses to the inverter’s semiconductor switching devices to maintain or change the motor torque as required.

The lookup table provides the optimum voltage vector based on three parameters: whether torque and stator flux each need to be increased or decreased (or, for torque, held constant), and in which sector (60 degree segment) of the space vector plane the stator flux resides.

direct torque control

A classic lookup table, used by the optimum pulse selector to determine the optimum voltage vector for changing or maintaining motor torque.

The semiconductor switching in the inverter again determines motor voltage and current, which determines motor torque and flux, therefore closing the control loop.

6 –The speed control loop contains a speed controller (which consists of a PID controller and an acceleration compensator), a torque reference controller, and a flux reference controller.

The output of the speed controller is fed to the torque reference controller, whose output is the internal reference value for the torque comparator in the torque control loop.

通量参考控制器决定呈献te stator flux value and provides this as the internal reference for the flux comparator in the torque control loop. The flux reference controller is also where flux is controlled and modified to enable inverter functions such as energy optimization and flux braking.


When direct torque control is compared to field oriented control, which also allows tight control of motor speed and torque, two primary differences stand out. First, direct torque control is sensorless — no speed or position encoders are required. It only requires voltage and current measurements. This reduces cost and improves reliability.

The second difference is that direct torque control doesn’t require a modulator (pulse-width modulator, or PWM), so processing time is reduced by a factor of 10, which improves torque response, typically to less than 2 ms. This means torque and speed can be accurately controlled even at low speeds, and full start-up torque is available all the way down to zero speed.


Filed Under:Motion Control Tips


Related ArticlesRead More >

Customized and reliable stepper motors address HVAC damper application extremes
What are electromagnetic power-off brakes and where are they used?
New compact servo motor features integrated positioning controller
Low-profile kit-style limited angle torque motor

MOTION DESIGN GUIDES

“motion

Enews Sign Up

Motion Control Classroom

Design World Digital Edition

cover

Browse the most current issueof Design World and back issues in an easy to use high quality format. Clip, share and download with the leading design engineering magazine today.

EDABoard the Forum for Electronics

Top global problem solving EE forum covering Microcontrollers, DSP, Networking, Analog and Digital Design, RF, Power Electronics, PCB Routing and much more

EDABoard: Forum for electronics

Sponsored Content

  • Inventive ways to use ultra-wideband and what you need to know to get started
  • HELUKABEL PVC Control & Motor Cables Receive ECOLAB Certification
  • Electronic valve technology
  • Special Rings: Self-Locking, Balanced, ID/OD Lock
  • Five Reasons: The 2065 Connector is a Reliable Alternative to Manual Soldering
  • Drilling rig OEM benefits from a PLC with edge computing technology: IIoT case study
Engineering Exchange

The Engineering Exchange is a global educational networking community for engineers.

Connect, share, and learn today »

Tweets by @DesignWorld
Design World
  • Advertising
  • About us
  • Contact
  • Manage your Design World Subscription
  • Subscribe
  • Design World Digital Network
  • Engineering White Papers
  • LEAP AWARDS

Copyright © 2021 WTWH Media LLC. All Rights Reserved. The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of WTWH Media
Privacy Policy|Advertising|About Us

Search Design World

  • Home
  • Articles
    • 3D CAD
    • Electronics • electrical
    • Fastening & Joining
    • Factory automation
    • Linear Motion
    • Motion Control
    • Test & Measurement
    • Sensors
  • 3D CAD Models
    • PARTsolutions
    • TraceParts
  • 领导
    • 2020 Winners
    • 2019 Winners
    • LEAP Awards
  • Resources
    • Subscribe
    • DIGITAL ISSUES
      • EE World Digital Issues
    • Future of Design Engineering
    • LEAP Awards
    • MC² Motion Control Classroom
    • Motion Design Guide Library
    • Podcasts
    • Suppliers
    • Webinars
  • Women in Engineering
  • Ebooks / Tech Tips
  • Videos
  • COVID-19
We use cookies to personalize content and ads, to provide social media features and to analyze our traffic. We also share information about your use of our site with our social media, advertising and analytics partners who may combine it with other information that you’ve provided to them or that they’ve collected from your use of their services. You consent to our cookies if you continue to use this website. OkNoRead more