Hardy Hi 1734-WS点I / O重量处理模块最近部署到经济上更换用于测量管道挤出机上的力的旧模拟应变计调节器。立即,HI 1734-WS模块显着降低了旧模拟应变计调节器的校准和设置时间。
每台机器96个信道的应变计的输入,每个场和微调微调电位,使用小螺钉驱动器和稳定的手的过程中拨号被要求手动数百“tweeks”的。“当我们在第96个传感器上进行微调完成时,首先需要再次调整”。使用HI 1734-WS模块的C2®失重校准,现在可以使用软件命令完成几乎永久过程的内容;校准在单击按钮时自动预先格式化。同样地,Hi 1734-WS还可以在漂移之后重新归零设备,而不是用螺丝刀进行手动调节。
第二份益处是提高产品质量和产品一致性。Replacing the 16-bit analog input modules with Hardy’s 24-bit digital solution not only improved resolution of the process by a factor of 200X, but the process also benefited from Hardy’s advanced digital filtering technique called WAVERSAVER® that virtually eliminates electrical noise and mechanical vibrations inherent to the equipment. The noise and vibrations were the source of constant erroneous readings back to the control system – causing the process to hunt for adjustments that weren’t necessary and ultimately caused deviations in pipe wall thickness. With greater resolution and the elimination of erroneous readings – wall thickness can now be controlled (using the same mechanics) to a level never seen before on the equipment.
Hardy Process Solutions产品开发经理Timothy Norman说:“这个模块非常容易安装、设置、校准和维护。HI 1734-WS是一个真正的重量处理模块,专为点I/O系统,而不是通过原始的a /D计数通过PLC进行解释的竞争模型。使用Rockwell Automation Add-On-Profile (AOP)和易于使用的Faceplate也很容易配置。
HI 1734-WS非常适用于快速,稳定的重量数据和低的所有权成本很重要的应用。它旨在成为模拟变送器的高性能更换,具有噪声过滤的优点,以及大大尺度的稳定时间。它是超紧凑,减少机器成本和控制柜占地面积。该模块还包括Hardy Process Toolbox特征:C2失重校准,集成技术型系统诊断和机械振动的Waversaver免疫力。
提交:模拟IC提示





告诉我们你的想法!